Door Interlocking System Specification

  • Operating Mode
  • Interlocked, Sequential, Forced Lock Override, Emergency Release
  • Connectivity Type
  • Terminal Strip/Wiring Harness, Expansion Options
  • Standard
  • Customizable to Site Safety Standards, Complies with International Electrical Safety Standards
  • Size
  • Custom Enclosure Sizes Available
  • License Free
  • Yes
  • Interface
  • Keypad, Magnetic/Electric Locks, Access Control Reader Interfaces
  • Mounting Type
  • Wall Mount, Panel Mount
  • Technology
  • Microcontroller-Based Electronic System
  • Special Features
  • Sequential Door Access Control, Visual and Audio Status Indication, Emergency Override, Tamper Proof, Compatible with Access Control, Fail Safe and Fail Secure Modes
  • Remote Control
  • Supported with Wired or Optional Wireless Module
  • Application
  • Industrial Labs, Cleanrooms, Server Rooms, Pharmaceuticals, Data Centers, Biotech, Hospitals, Processing Plants
  • Power Supply
  • 230V AC, 50Hz
  • Output Formats
  • Dry Contact Relay Outputs
  • Indicator Type
  • Multi-Color LED for Door Status
  • Cable Entry
  • Bottom/Rear Entry Knock-Outs
  • Compliance
  • Designed for GMP and cGMP Applications
  • Control Method
  • Sequential Interlocking Logic, Time Delay Setting
  • Alarm Output
  • Buzzer/Siren Output on Fault or Unauthorized Entry
  • Wiring Type
  • Low Voltage Signal Cabling
  • Ingress Protection
  • IP30/IP54 Rated (Model Dependent)
  • Material
  • ABS/Metal Enclosure
  • Temperature Range
  • 0°C to 50°C Operation
  • Communication Options
  • Optional RS485/Ethernet Interface
  • Access Logging
  • Optional Event Log Module
  • Reset Method
  • Manual or Auto Reset
  • Number of Doors Supported
  • 2 to 8 Doors (Expandable)
 

Door Interlocking System Trade Information

  • Minimum Order Quantity
  • 1 , , Number
  • Supply Ability
  • 100 Per Month
  • Delivery Time
  • 7 Days
 

About Door Interlocking System

A Door Interlocking System prevents more than one door from opening at the same time, under normal conditions. It is electrically operated using magnetic locks and magnetic door switches. Pushbuttons installed at the doors are for overriding the magnetic locks in the event of an emergency. It is one of the most secure methods of access control available to site security managers. The Door Interlocking System is made available by us for efficient use. 

Product Details :

Minimum Order Quantity

2 Piece

Suitable For

Pharma Companies Clean Rooms

Lock Operation

Electronic logic controlled

Keys

No keys

Ideal For

Pharmaceutical companies

Handle Size

No handle

Brand

OFORT

Color

SS

Power/Voltage

12V 24V

Usage/Application

Pharmaceutical Air Locks, Change rooms, Labs, Hospitals, R&D centers, Clean Rooms, passbox, Air Shower

Features

Door Interlocking system 2Door,3Door,4Door and more. Doors be programmed to interlock with other



Advanced Sequential Interlocking Logic

Our door interlocking solution utilizes microcontroller-based technology to enforce controlled, one-at-a-time access between multiple doors. This prevents cross-contamination and maintains security, making it ideal for cleanrooms, pharmaceuticals, biotech, and secure data environments. The system's sequential and interlocked logic minimizes accidental or unauthorized area crossover while supporting emergency override and manual or automatic reset options.


Flexible Installation and Robust Build

Designed for easy deployment, this system is available in wall or panel mount models with customizable enclosure sizes and mounting options. Featuring ABS or metal enclosures and ingress protection up to IP54, the system accommodates harsh industrial settings. Cables can enter via bottom or rear knock-outs, and low voltage signal cabling ensures safe, straightforward wiring.


Comprehensive Safety and Integration Features

With alarm outputs (buzzer/siren), visual audio status indicators, and compatibility with keypads, access control readers, and various locks, the system delivers thorough security and monitoring. It includes expansion options, event logging (optional), remote control via wired or wireless modules, and dry contact relay outputs. The system is compliant with GMP, cGMP, and international electrical safety standards for reliable, regulated operation.

FAQ's of Door Interlocking System:


Q: How does the Door Interlocking System control multiple doors for secure access?

A: The system uses sequential interlocking logic managed by a microcontroller, ensuring only one door can be opened at a time. This coordinated control prevents simultaneous access, reducing contamination and enhancing security in restricted zones like cleanrooms or data centers.

Q: What happens if there is an unauthorized entry or door fault?

A: If a door is forced open or a fault is detected, the system immediately triggers an audible alarm via a buzzer or siren. Multi-color LED indicators also provide visual alerts, ensuring prompt awareness and response to unauthorized access or system faults.

Q: Where can this interlocking system be installed, and is it customizable?

A: The system supports installation in a variety of environments including pharmaceuticals, laboratories, hospitals, data centers, and industrial processing plants. Enclosure sizes and mounting configurations are customizable to match specific site requirements and safety standards.

Q: What options are available for access control and system integration?

A: It integrates with access control readers, keypads, magnetic and electric locks, and is compatible with wired or optional wireless remote modules. Additional options for Expansion, event logging, and communication interfaces such as RS485 or Ethernet are available.

Q: How is the Door Interlocking System reset after an event or emergency?

A: The system can be reset either manually or through an auto-reset functionality, depending on user preference and configuration. Emergency release and forced lock override modes are also provided for rapid access during critical situations.

Q: What are the benefits of using this system in compliance-regulated sites?

A: Designed specifically to meet GMP and cGMP standards, the system ensures secure, traceable, and fail-safe access control. Its tamper-proof, robust build and comprehensive logging capabilities help maintain regulatory compliance and enhance overall safety.

Q: What type of power supply and wiring is used for installation?

A: The system operates on a 230V AC, 50Hz power supply and uses low voltage signal cabling for safe, easy installation. Connectivity is provided by terminal strip or wiring harness, with cable entry from the bottom or rear knock-out points.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email



Back to top